Black Friday at CARTVOS✦Free UK delivery✦14-day free returns✦Secure card payments✦Black Friday at CARTVOS✦Free UK delivery✦14-day free returns✦Secure card payments✦
Bimson Power ATS - Automatic Transfer Switch for Diesel Generators
Bimson Power

Bimson Power ATS - Automatic Transfer Switch for Diesel Generators

Black Friday at CARTVOS

Current pricing and availability are shown below, with free UK delivery and 14-day free returns.

£258.34

Free UK delivery · Dispatched in 1–2 business days · Delivered in 3–7 business days in total

14-day free returns · Free return label · No restocking fee

Order today, estimated delivery Tue 24 Nov – Mon 30 Nov

In stock· Ready for dispatch

1
Accepted payment methods
  • VISA
  • AMEX
  • Payment
Overview

Product details

Automatically starts a compatible diesel generator during a mains failure and transfers essential loads to backup power.

Supports 230 V single-phase and 415 V three-phase installations, with a built-in 2 A battery charger.

Automatic backup power for compatible diesel generators

The BIMSON POWER ATS Automatic Transfer Switch for Diesel Generators provides automatic mains-to-generator changeover for compatible generators with an ATS connection. It monitors the incoming mains supply, starts the generator when supply is lost or low, and transfers the connected load once generator power is available.

Key features

ATS multi phase panel

suits all Warrior diesel models from 4kW to 15kW in both single & three phase (MUST have ATS Input socket on generator panel)

Automatic start and changeover:

starts a compatible generator within six seconds of a mains failure or low incoming supply.

Automatic mains restoration:

transfers back to mains power on restoration and stops the generator approximately 15 seconds later.

Single- and three-phase support:

wiring diagrams are provided for 230 V single-phase and 415 V three-phase systems.

Built-in battery charger:

2 A battery charging current helps maintain the generator starter battery while the generator is not running.

Fault indication and manual override:

red fault light, three automatic start attempts, Auto/Manual control and an internal manual lever override.

Where to use

Suitable for compatible BIMSON POWER and Warrior diesel generators with the required ATS port. It is intended for emergency standby applications where automatic generator start and controlled changeover are needed for a dedicated consumer unit, essential circuits or selected equipment.

This product must be installed and commissioned by a qualified electrician or trusted generator-installation partner. They must confirm generator compatibility, phase configuration, cable and protective-device sizing, earthing, neutral arrangement and anti-backfeed protection before use.

Technical specifications

BIMSON POWER ATS Installation and Operator Manual

Shipping

or

for a quote.

UK expert support

Key Features

  • Automatically starts a compatible diesel generator during a mains failure and transfers essential loads to backup power.
  • Supports 230 V single-phase and 415 V three-phase installations, with a built-in 2 A battery charger.
  • ATS multi phase panel suits all Warrior diesel models from 4kW to 15kW in both single & three phase (MUST have ATS Input socket on generator panel)
  • Automatic start and changeover: starts a compatible generator within six seconds of a mains failure or low incoming supply.
  • Automatic mains restoration: transfers back to mains power on restoration and stops the generator approximately 15 seconds later.
  • Single- and three-phase support: wiring diagrams are provided for 230 V single-phase and 415 V three-phase systems.
  • Built-in battery charger: 2 A battery charging current helps maintain the generator starter battery while the generator is not running.
  • Fault indication and manual override: red fault light, three automatic start attempts, Auto/Manual control and an internal manual lever override.
  • BIMSON POWER ATS Installation and Operator Manual

Specifications

  • Model: 190102000010
  • Product type: Automatic Transfer Switch (ATS) panel for diesel generators
  • Supported supply configurations: 230 V single-phase; 415 V three-phase
  • ATS current rating: 100 A
  • Generator start timing: Within 6 seconds of mains supply loss or low supply
  • Generator load application: After approximately 5–6 seconds of generator running in automatic mode
  • Start attempts: 3 attempts; red fault indicator illuminates if unsuccessful
  • Mains restoration / generator stop: Load transfers to mains; generator stops approximately 15 seconds later
  • Battery charger: Built-in; 2 A charging current
  • Controls: Auto/Manual button, key switch, manual handle and padlock isolation provision
  • Indicators: Mains supply, generator supply, automatic mode and red fault indication
  • ATS port configuration: 12 V power; start relay; fuel oil; flywheel-frequency sensing
  • Generator control cable: ATS input cable supplied for connection to the generator control panel
  • Diesel-generator ignition position for automatic operation: OFF
Frequently asked

Good to know.

Free standard delivery to your address anywhere in the United Kingdom. Orders placed before 2:00 PM (UK time) on a business day are prepared for dispatch within 1–2 business days (Monday–Friday), then delivered within 2–5 business days (Monday–Friday) — 3–7 business days in total.

You can return any item within 14 days of delivery, whether it is faulty or you have simply changed your mind. Exchanges are accepted. Returns are sent back by mail with a free prepaid return label that we provide — there is no restocking fee. Refunds are issued to your original payment method within 14 days of us receiving your return. Items must be returned new, unused and unassembled, in their original packaging with all parts. If an item arrives damaged or faulty, contact us within 14 days with photos and we will arrange a free collection, replacement or full refund.

All payments are encrypted and processed securely. We never see or store your payment details.

The product description and technical specifications above contain the stored model information, included items and compatibility details.

Bimson Power ATS - Automatic Transfer Switch for Diesel Generators

£258.34