Run suitable off-grid loads without solar panels, using battery power between generator charging sessions.
Victron MultiPlus-II provides 230V pure sine wave power, rated at 3kVA / 2.4kW continuously at 25°C.
Dyness Powerbox G2 provides 10.24kWh nominal lithium storage, paired with a separately specified 5.5–6.5kW-class generator.
Off-grid battery and generator power without solar
This Victron 3kVA off-grid energy system combines a MultiPlus-II 48/3000/35-32 inverter-charger, a Dyness Powerbox G2 LiFePO₄ battery and a selected generator in the 5.5–6.5kW class. The generator supplies accepted AC power and recharges the battery through the inverter-charger. When it stops, suitable connected loads continue to operate from stored energy without requiring solar panels.
Key features
No solar required: suitable where shading, limited space, seasonal use or site restrictions make a solar array impractical.
Battery operation between charging sessions: supply suitable loads without running the generator continuously. Actual generator hours depend on consumption and charging requirements.
Managed generator loading: PowerControl limits AC input demand, while PowerAssist can supplement an accepted generator supply with battery power when correctly configured.
Dyness lithium storage: 10.24kWh nominal capacity, IP65 protection and CAN/RS485 communication, with floor- or wall-mounted installation options.
Where to use
Consider this system for remote offices, cabins, rural outbuildings, seasonal accommodation, communications equipment and selected small-business loads where grid power or solar generation is unavailable or unsuitable.
Check daily energy demand, simultaneous loads and starting currents before specifying the package. The inverter’s continuous battery-powered output is 2.4kW at 25°C; a larger generator does not increase that battery-only rating.
How the system works
With the generator stopped, the inverter converts battery DC power into 230V AC. When an acceptable generator supply is connected, the MultiPlus-II supplies the loads and uses available input capacity to charge the battery, within the commissioned limits.
The inverter charger is rated at 35A. A larger generator does not increase charging beyond this limit. Generator loads, charging demand and any PowerAssist contribution must be managed within the generator outlet, inverter, battery, cable and protection ratings.
No solar required does not mean no energy input is required: generator fuel replenishes the battery. Runtime, recharge time and fuel use depend on the load profile, generator model and operating settings; no fixed performance figures are guaranteed.
Proposed package contents
1 ×
Victron MultiPlus-II 48/3000/35-32 230V inverter-charger
.
1 ×
Dyness Powerbox G2 51.2V 200Ah LiFePO₄ battery
, rated at 10.24kWh nominal energy.
1x
Victron Cerbo GX
and
Victron GX Touch 50
display,
1x
Könner & Söhnen KS 9200HDES-1/3 ATSR (EURO 5) 6.0kW (230V) 7.0kW (400V) Diesel Generator
, or
1x
Könner & Söhnen KS 7000E G 5.5kW Dual-Fuel LPG/Petrol Generator
1x Complete set of cables, connectors, disconnectors, and accessories.
Installation and commissioning
Dyness lists Victron Energy among compatible inverter brands. Confirm the exact battery firmware, approved communication cable, GX requirements and inverter settings before commissioning. Do not assume the inverter’s default charging profile is suitable for the battery.
Automatic generator starting is assumed. It requires a compatible generator and an approved control interface. A combustion generator must operate outdoors in a safe location away from doors, windows and air intakes—not inside the battery or inverter enclosure.
Technical specifications
Inverter specifications follow the attached Victron datasheet’s 48/3000/35-32 model. Battery specifications follow the attached Dyness Powerbox G2 datasheet, version 20241231-EN. Generator-specific data will be added when the model is selected.
Victron MultiPlus-II inverter-charger datasheet
Victron MultiPlus-II installation and user manual
Dyness Powerbox G2 datasheet
Dyness Powerbox G2 user manual
Shipping
or
for a quote.
UK expert support
Key Features
- Run suitable off-grid loads without solar panels, using battery power between generator charging sessions.
- Victron MultiPlus-II provides 230V pure sine wave power, rated at 3kVA / 2.4kW continuously at 25°C.
- Dyness Powerbox G2 provides 10.24kWh nominal lithium storage, paired with a separately specified 5.5–6.5kW-class generator.
- No solar required: suitable where shading, limited space, seasonal use or site restrictions make a solar array impractical.
- Battery operation between charging sessions: supply suitable loads without running the generator continuously. Actual generator hours depend on consumption and charging requirements.
- Managed generator loading: PowerControl limits AC input demand, while PowerAssist can supplement an accepted generator supply with battery power when correctly configured.
- Dyness lithium storage: 10.24kWh nominal capacity, IP65 protection and CAN/RS485 communication, with floor- or wall-mounted installation options.
- 1 × Victron MultiPlus-II 48/3000/35-32 230V inverter-charger .
- 1 × Dyness Powerbox G2 51.2V 200Ah LiFePO₄ battery , rated at 10.24kWh nominal energy.
- 1x Victron Cerbo GX and Victron GX Touch 50 display,
- 1x Könner & Söhnen KS 9200HDES-1/3 ATSR (EURO 5) 6.0kW (230V) 7.0kW (400V) Diesel Generator , or
- 1x Könner & Söhnen KS 7000E G 5.5kW Dual-Fuel LPG/Petrol Generator
- 1x Complete set of cables, connectors, disconnectors, and accessories.
- Victron MultiPlus-II inverter-charger datasheet
- Victron MultiPlus-II installation and user manual
- Dyness Powerbox G2 datasheet
- Dyness Powerbox G2 user manual
Specifications
- Specification: Value
- System type: Single-phase, generator-charged off-grid energy system
- Solar requirement: No solar panels required for the proposed generator/battery operation
- Inverter-charger: Victron MultiPlus-II 48/3000/35-32, 230V
- Battery model: Dyness Powerbox G2
- Battery chemistry: LiFePO₄ / lithium iron phosphate
- Nominal battery voltage: 51.2V; 48V-class system
- Nominal battery capacity: 200Ah
- Nominal stored energy: 10.24kWh, described as approximately 10.2kWh in the product title
- Recommended depth of discharge: 90%
- Energy at 90% discharge allowance — calculated: 9.216kWh of nominal battery energy before inverter losses and operating restrictions
- Generator selection: 5.5–6.5kW class
- Future solar integration: Possible using separately specified compatible MPPT solar charge controller; the MultiPlus-II does not contain a PV MPPT controller
- Continuous apparent output at 25°C: 3,000VA
- Continuous active output at 25°C: 2,400W
- Continuous active output at 40°C: 2,200W
- Continuous active output at 65°C: 1,700W
- Peak inverter power: 5,500W; system surge capability also depends on battery voltage, BMS limits, cabling and protection
- Output voltage: 230V AC ±2%
- Output frequency: 50Hz ±0.1%
- Output waveform: Pure sine wave
- DC input-voltage range: 38–66V DC; actual operation must remain within the connected battery’s permitted range
- Maximum inverter efficiency: 95% for the 48V 3kVA model
- Zero-load consumption: 11W
- Zero-load consumption in AES mode: 7W
- Zero-load consumption in Search mode: 2W
- Maximum apparent feed-in power: 3,000VA component rating; grid export is not part of this off-grid package
- AC transfer time: Less than 20ms, as described by Victron
- AC input-voltage range: 187–265V AC
- AC input-frequency range: 45–65Hz
- Maximum AC input current: 32A; commission a limit appropriate to the generator, outlet, cable and protection
- Transfer-switch rating: 32A
- Maximum battery charging current: 35A, up to 25°C ambient, subject to available AC input and battery limits
- Battery temperature sensor: Supported; follow the approved lithium battery/BMS configuration
- PowerControl: Reduces charging demand to respect the configured AC input-current limit
- PowerAssist: Allows battery power to supplement an accepted AC source when enabled and correctly configured
- AC output 1: Main inverter-backed output
- AC output 2: 32A auxiliary output, available only when accepted AC input is present
- Programmable relay: Configurable for general alarm, DC undervoltage or generator start/stop signalling
- Relay AC contact rating: 230V AC / 4A
- Relay DC contact rating: 4A up to 35V DC; 1A up to 60V DC
- VE.Bus communication: System integration, remote monitoring and supported parallel/three-phase configurations
- General-purpose communication ports: 2
- Remote on/off: Supported
- Optional external AC current sensor: 50A or 100A, as applicable; does not increase this model’s 32A AC input rating
- Remote monitoring: Optional Cerbo GX with internet connection to Victron VRM
- VRM platform: Free remote monitoring platform
- Local configuration: VEConfigure with suitable computer/interface
- Optional Bluetooth: VE.Bus Smart Dongle; not assumed included
- Parallel/three-phase capability: Supported with matching compatible units and a redesigned installation; this listing includes one inverter only
- Cooling: Fan-assisted
- Operating temperature: −40°C to +65°C; output derating applies
- Maximum humidity: 95%, non-condensing
- Enclosure material and colour: Steel, blue RAL 5012
- Inverter ingress protection: IP22; install in a suitable protected location
- Battery terminals: M8 bolts
- 230V AC terminals: Screw terminals, up to 13mm² / 6AWG, as stated in the supplied datasheet
- Dimensions, H × W × D: 499 × 268 × 141mm
- Inverter weight: 19kg
- Protection functions: Output short circuit, overload, high/low battery voltage, overtemperature, external 230V at inverter output and excessive DC input ripple
- Safety references: EN-IEC 60335-1; EN-IEC 60335-2-29; EN-IEC 62109-1; EN-IEC 62109-2
- Emission and immunity references: EN 55014-1; EN 55014-2; EN-IEC 61000-3-2; EN-IEC 61000-3-3; IEC 61000-6-1, -6-2 and -6-3
- UPS and anti-islanding approvals: Refer to the applicable model-specific certificates on Victron’s website; no additional approval is inferred for this complete package.
- Battery type: LiFePO₄
- Nominal battery energy: 10.24kWh
- Nominal voltage: 51.2V
- Operating-voltage range: 44.8–57.6V
- Nominal capacity: 200Ah
- Nominal charge/discharge power: 5.12kW
- Max discharge power: 10.24kW
- Recommended charge/discharge rate: 0.5C
- Recommended charge/discharge current: 100A
- Recommended depth of discharge: 95%
- Battery/inverter power distinction: The battery’s power ratings do not increase the inverter’s 2.4kW continuous battery-powered AC output.
- Communication: CAN / RS485
- Wi-Fi module: Optional
- Battery protection level: IP65
- Dimensions, W × D × H: 700 × 165 × 640mm
- Battery net weight: 96kg
- Installation options: Wall-mounted or floor-mounted
- Charging-temperature range: 0°C to +55°C
- Discharging-temperature range: −20°C to +55°C
- Cold-weather charging: Do not charge below the specified minimum cell temperature. A separate approved temperature-management solution is required where necessary.
- Published safety features: Short-circuit lockout and surge resistance
- Battery equalisation feature: Manufacturer lists support for mixing modules at different states of charge; follow its approved expansion procedure. This is not permission to enable lead-acid equalisation charging.
- Expansion: Up to 50 compatible units in parallel
- Cycle life: Unlimited cycles, 10 years
- Certification and safety references listed: UN38.3; CE-EMC; IEC62619; IEC62040; UKCA; CEC
- Generator range: 5.5–6.5kW class; one selected generator per package
- Required electrical output: Compatible single-phase 230V AC supply with sufficient continuous output at the selected outlet
- Rating basis: Identify continuous and maximum generator ratings separately before quotation.
- Single-phase availability: A generator’s total three-phase rating must not be treated as its available single-phase output.
- Available charging current: Limited to the inverter’s 35A charger rating, available generator power and the commissioned battery limits
- Generator fuel, tank, noise and runtime: To be specified from the selected generator’s manufacturer documents
- Generator dimensions and weight: To be confirmed for the selected model
- Combined inverter and battery weight: 115kg, excluding generator, cables, protection equipment and enclosure
- Weather protection: No single overall IP rating claimed. Each component requires a suitable installation location.
- Final commissioning checks: Battery communication, charging limits, generator acceptance, load steps, PowerAssist operation, earthing and protective-device coordination
Good to know.
Free standard delivery to your address anywhere in the United Kingdom. Orders placed before 2:00 PM (UK time) on a business day are prepared for dispatch within 1–2 business days (Monday–Friday), then delivered within 2–5 business days (Monday–Friday) — 3–7 business days in total.
You can return any item within 14 days of delivery, whether it is faulty or you have simply changed your mind. Exchanges are accepted. Returns are sent back by mail with a free prepaid return label that we provide — there is no restocking fee. Refunds are issued to your original payment method within 14 days of us receiving your return. Items must be returned new, unused and unassembled, in their original packaging with all parts. If an item arrives damaged or faulty, contact us within 14 days with photos and we will arrange a free collection, replacement or full refund.
All payments are encrypted and processed securely. We never see or store your payment details.
The product description and technical specifications above contain the stored model information, included items and compatibility details.
Compare similar products.

Generators
Bimson Power 12.5 kVA 3 Phase Diesel Generator - Wireless Start

Generators
Bimson Power 12.5 kVA Single Phase Diesel Generator

Generators
Bimson Power ATS - Automatic Transfer Switch for Diesel Generators

Generators
Champion 2200 Watt "Mighty Atom" Petrol Inverter Generator
Victron 3kVA 48V Off-Grid Energy System with 10.2kWh LiFePO₄ Battery and 5.5-6.5kW Generator - No Solar Required
£3,407.82